STATION LINE STATUS DISPLAY
General Description
This feature displays the line status for a single line telephone or a D
term
using the CAT or the
MAT.
Service Conditions
(1)
This feature is not available when the system is off-line.
(2)
When performing this feature for a single line telephone, this feature may affect the status
of the other telephone in the same line circuit card. Therefore, use this feature only when a
line fault has occurred (do not use under a normal state).
Programming Procedure
No programming is required.
Operating Procedure
Operation:
Explanation of Screen Information:
Station Number: X-XXXXXXXX (1-8 digits)
Analog Line/Digital Line
00: LC (Single Line Tel.)
10: DLC (D
term
)
Hardware Test
See
EC1
DE
+
EC1>
ST
COMMAND=
X-XXXXXXXX
DE
+
XXXXXXXX : XX XX XX
(STATION NO.)
XXXXXXXX : XX XX XX
4
2
1
3
1
2
3