NEAX2000
IVS
2
Maintenance Manual
Page 32
ND-70926
(E),
Issue
3.0
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Battery Release Control
Operating Procedure
(1)
To disconnect the battery:
(2)
To cancel the battery disconnection:
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:1 –
00
EXE
+
EC0>00:1 – 0
0
OK
THE CURRENT STATUS DISPLAYS AFTER ENTERING FIRST DATA 00
(1: BATTERY CONNECTION)
THE STATUS CHANGES TO BATTERY DISCONNECTION AFTER
ENTERING SECOND DATA 0.
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:0 –
00
EXE
+
EC0>00:0 – 1
1
OK
THE CURRENT STATUS DISPLAYS AFTER ENTERING FIRST DATA 00
(0: BATTERY DISCONNECTION)
THE STATUS CHANGES TO BATTERY CONNECTION AFTER ENTERING
SECOND DATA 1.