CHAPTER 2 TROUBLESHOOTING
Precautions
NEAX2000 IVS
2
Maintenance Manual
ND-70926 (E), Issue 3.0
Page 63
Turning Power ON
(1)
Check the switch position of each PZ-PW121/PZ-PW126 card before turning power on.
• Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for
each country (AC120V or AC240V).
NOTE: PZ-PW126 does not have this switch.
• Make sure that the battery mode selector switch is positioned for a Sealed or Vented
battery, as shown below.
(2)
Turn the SW1 switches of all the PZ-PW121/PZ-PW126 cards to ON. First, turn ON PIM1
to PIM7. Then, turn ON PIM0 last of all.
Turning Power OFF
(1)
Before turning power OFF; make sure that all line/trunk cards are not operating with no busy
lamps indication.
(2)
Turn the SW1 switches of all the PZ-PW121/PZ-PW126 cards to OFF. First, turn OFF PIM0.
Then, turn OFF PIM1 to PIM7.
CAUTION
1. When the operating power is being supplied to the PZ-PW121/PZ-PW126 card, do not plug/
unplug this circuit card into/from its mounting slot.
2. When the system is configured with two or more PIMs, the BUS cable is providing gang
control for the PZ-PW121/PZ-PW126 card of PIM0 and other PIMs. Therefore, if the power
of PIM0 is off, no power is supplied to the whole system even when the power switch(es) of
other PIMs are left on.
NOTE: The battery charging is continuing even under these circumstances.
3. Do not turn off the PZ-PW121/PZ-PW126 card on PIM1 to PIM7 when the system is
operating.
SW
240V
100V/120V
ON
OFF
12
SW101
1 : Not used
2 : ON (SEAL/FLOAT 2)
OFF (OPEN/FLOAT 1)
Summary of Contents for NEAX 2000IVS2
Page 1: ...ND 70926 E ISSUE 3 PART OF STOCK 151969 Maintenance Manual FEBRUARY 2001 NECAmerica Inc...
Page 152: ...NEAX2000 IVS2 Maintenance Manual Page 144 ND 70926 E Issue 3 0 This page is for your notes...
Page 156: ...NEAX2000 IVS2 Maintenance Manual Page 148 ND 70926 E Issue 3 0 This page is for your notes...