DATA PROGRAMMING
Data Programming Procedure for Add-On Module
4. Data Programming Procedure for Add-On Module
When assigning Add-On Module data, perform the following procedure. “X” indicates the value should be tai-
lored to the existing system.
STEP 1:
ASDT
Assign a D
term
to an even-numbered LEN level. (In this example, LV 0 is used.) Assign the Add-On
Module to the subsequent odd-numbered LEN level. (In this example LV 1 is used.)
STEP 2:
AKYD
Assign Line/Feature access keys to the Add-On Module. The upper 24 Line/Feature access keys be-
long to the associated D
term
and the remaining lower 36 Line/Feature access keys belong to the Add-
On Module.
Use the associated D
term
port to assign information for the D
term
and first 24 keys on the ADM.
TN
:
X
STN :
201
LEN :
0 0 0 1 0 1
Odd-numbered LEN level
TEC :
1 2
Fixed
RSC :
X
SFC :
X
TN
:
X
STN
:
200
TP
:
1
Buttons 1-39 are assignable
PRI
:
0
PL TN
:
X
PL STN
:
200
S
:
0
= Off Hook Suppression is off
MWD
:
X
LN PRE
:
0
= Prime Line Pickup
KYN
:
1-16
For D
term
17-40
Correspond to KYNs (1-24) on the Add-On Module
KY1
:
X
KD
:
X
TN
:
X
STN
:
XXXX
RG
:
X
ICM
:
X
G-ID
:
X
Summary of Contents for NEAX 2400 IMX
Page 4: ...TABLE OF CONTENTS ND 70684 E Page ii Revision 1 0 This page is for your notes...
Page 6: ...LIST OF FIGURES ND 70684 E Page iv Revision 1 0...
Page 8: ...LIST OF TABLES ND 70684 E Page vi Revision 1 0 This page is for your notes...
Page 22: ...CHAPTER 1 ND 70684 E Page 14 Revision 1 0 This page is for your notes...
Page 26: ...CHAPTER 2 ND 70684 E Page 18 Revision 1 0 This page is for your notes...
Page 50: ...CHAPTER 3 ND 70684 E Page 42 Revision 1 0 This page is for your notes...