CHAPTER 5
NDA-24305
Page 98
Revision 1.0
LEAST COST ROUTING-3/6-DIGIT-PRI
STEP 12: AFRS - List the dialing patterns in groups that will be served by a specific sequence of routes. This
determination of routes is labeled as an Outgoing Pattern Route (OPR). In AFRS, program
the Tenant, Route Number (Dummy Route), The Number Code or dialing patterns, and the
OPR to be chosen when these digits are dialed.
STEP 13: AOPR - The AFRS command designates the dialing sequence and the OPR to be selected. The
AOPR defines the routes and in what order these routes will be selected. Assign the
following:
TDPTN No. : Time of Day Pattern Change. If an AFRS assignment, different OPRs will
be required as a function of time. Designate 1-7 for the Time-of-Day Pattern
Change Number (TDPTN) to which this OPR is assigned.
OPR No. :
Outgoing Pattern Route. The number referenced in AFRS, consisting of a
series of routes to be chosen based on number dialed.
Route Advance Number (RA) :
The order in which a route will be selected (0-7).
Route Advance End Display (E) :
The last route in the route advance group is indicated
with data “0”. All others are indicated with data “1”.
Route Number :
The physical Route Number to be selected as programmed in ARTD.
Skip Digits :
The digits to be skipped when translating the dialed digits in AFRS.
Pattern Number Location :
If digits are to be added after translating the dialed digits in
AFRS, assign a PNL. The digits to be added are
programmed to the respective PNLs in the AADC
command. If no digits are to be added, PNL = 0 should be
assigned.
Overflow Tone : Assign if a tone is wanted for the Last Choice Route. If so, assign data
“1” for DDD.
Priority Restriction Class : Refer to PRIORITY RESTRICTION CLASS in the “EPN
Feature and Specification”. If this is required, assign PRSC
here, using classes 1-15. For all other systems, always assign
PRSC as data “0”.
STEP 14: AADC - If additional digits are required, assign the digits of a Pattern Number Location (PNL) here.
For additional digits totaling 24, use PNL 1-999.
STEP 15: ATCP - A maximum of eight Time-of-Day Pattern changes (0-7) are available whereby the system
will refer to different OPR assignments as a function of time.
Times Setting
TO:
FROM: (In Military Time, and only on the half-hour and hour.)
PATTERN NUMBER: (0-7).
Summary of Contents for NEAX 2400 IPX
Page 1: ...OCTOBER 2000 NEC America Inc NDA 24305 ISSUE 1 STOCK 200813 ISDN Feature Programming Manual...
Page 2: ......
Page 4: ......
Page 10: ......
Page 16: ...LIST OF FIGURES NDA 24305 Page vi Revision 1 0 This page is for your notes...
Page 18: ...LIST OF TABLES NDA 24305 Page viii Revision 1 0 This page is for your notes...
Page 20: ...CHAPTER 1 NDA 24305 Page 2 Revision 1 0 This page is for your notes...
Page 24: ...CHAPTER 2 NDA 24305 Page 6 Revision 1 0 This page is for your notes...
Page 178: ...CHAPTER 5 NDA 24305 Page 160 Revision 1 0 This page is for your notes...
Page 316: ...CHAPTER 6 NDA 24305 Page 298 Revision 1 0 This page is for your notes...