NDA-24305
CHAPTER 6
Page 195
Revision 1.0
MEGACOM800 SERVICE
M-77
MEGACOM800 SERVICE
1. General Description
AT&T’s MEGACOM 800 (INWARD WATS) network can be used.
Note 1:
When a call has terminated by the CALL-BY-CALL SERVICE SELECTION [C-105], no indication to
distinguish it from a call termination by other services is made to a terminating terminal.
Note 2:
To identify a terminal to which a call has terminated, data must be registered using the “ACDD” com-
mand so that a call-terminating terminal can be identified by a terminating number.
2. Operating Procedure
No manual operation is required.
3. Programming
In addition to the Basic Office Data for ISDN, the following data should be assigned.
STEP 1:
ACBC - Select CODE2 (=MEGACOM 800) in this command.
PRI
MEGACOM 800
2400
IPX
#4ES
MEGACOM