9-2
Issue 2 December 1995
Acceptance Tests
As explained in
INTUITY New System Planning,
585-310-603, two test
subscribers should have been administered on the switch for acceptance tests.
Acceptance tests begin after you complete initial administration and administer
two test subscribers on the INTUITY System. This chapter explains how to
administer two test subscribers on the NEAX 2400 MCI switch for performing
acceptance tests. If you have another type of switch, refer to the documentation
provided with that switch or the switch integration package for more information.
NOTE
:
The MCI link controls the message waiting indication. Four- and
eight-button Dterm telephones have a message waiting lamp. On a
16-button Dterm telephone, you see
VMM
on the display to tell you that you
have voice mail. Analog (2500) sets require neon lamps and the switch
must have an auxiliary 90V power supply to operate the lamps.
Continue with the procedures in this chapter to administer the switch for
acceptance tests. Before you proceed, though, select two test extensions to use
for acceptance tests. Use the test subscribers listed in
Intuiy New System
Planning,
585-310-603.
Administer the Test Subscribers
By forwarding a subscriber extension to the main extension of the Uniformed
Caller Distribution (UCD) group, the switch sends call information over the MCI
link to the SID. The SID converts and sends the information to the INTUITY
System. A call forwarded from the switch to the application is called an
integrated
call. You can set the following call forwarding conditions:
■
Forward subscribers for ring-no-answer
■
Forward subscribers for busy conditions
■
Forward subscribers for all calls
For acceptance tests, activate all three conditions.
Task 1: Forward Calls for Ring-No-Answer
Ring-No-Answer
(RNA) refers to an unanswered call. After a specific length of
time, set on the switch, without the call being answered, the call transfers to the
UCD group assigned to the INTUITY System.
NOTE
:
The test subscriber’s service feature class must contain call forward RNA
SFI=8. Dterm sets may have a function key for forward on busy (FKY=22).
For a station transferred blindly to a ring-no-answer station, the recall timer
takes priority over forward RNA. A call transferred to a busy extension
transfers back to the station that initiated the transfer.
Summary of Contents for NEAX 2400
Page 2: ...Blank Page ...
Page 8: ...Contents viii Issue 2 December 1995 ...
Page 36: ...2 10 Issue 2 December 1995 Switch Integration Device Basics ...
Page 42: ...3 6 Issue 2 December 1995 Switch Integration Planning ...
Page 52: ...4 10 Issue 2 December 1995 Hardware Installation ...
Page 70: ...6 10 Issue 2 December 1995 Administering the INTUITY System for the NEAX Integration ...
Page 104: ...8 16 Issue 2 December 1995 Switch Integration Device Administration ...
Page 122: ...A 10 Issue 2 December 1995 ...
Page 128: ...B 6 Issue 2 December 1995 ...