1-8
Issue 2 December 1995
Introduction and Requirements for Integration
Switch Integration Device Required Hardware
Table 1-1 lists the required SID components for the integration.
NOTE:
AT&T only assumes responsibility for connecting the Null cable and the
Y-cable to the SID. All remaining connections must be performed by the
customer or the customer’s switch technician.
Table 1-2. Switch Integration Device Hardware Components Required for the
Integration
Component
Description
AT&T
Supplied
Customer
Supplied
SID
AT&T Switch Integration Device,
Release 2
X
Null Cable
Used for connection to SID
X
Y-Cable
Used for connection from Null cable to
customer A25B Cable
X
A25B Cable
25-pair Amphenol female-to-female cable
used to connect Y-Cable and NEAX port
cable or MCI cable
X
MCI Cable
Cable that connects from the NEAX MCI
digital port to the A25B cable
X
Summary of Contents for NEAX 2400
Page 2: ...Blank Page ...
Page 8: ...Contents viii Issue 2 December 1995 ...
Page 36: ...2 10 Issue 2 December 1995 Switch Integration Device Basics ...
Page 42: ...3 6 Issue 2 December 1995 Switch Integration Planning ...
Page 52: ...4 10 Issue 2 December 1995 Hardware Installation ...
Page 70: ...6 10 Issue 2 December 1995 Administering the INTUITY System for the NEAX Integration ...
Page 104: ...8 16 Issue 2 December 1995 Switch Integration Device Administration ...
Page 122: ...A 10 Issue 2 December 1995 ...
Page 128: ...B 6 Issue 2 December 1995 ...