2-8 Setting Up the System
Status Indicator LED Descriptions
The following tables list the System Status Indicator LEDs, the Disk Drive
Status Indicator LEDs, the Disk Drive Status Abnormal Conditions, the Power
Supply Status Indicator LEDs, and the LAN Status Indicator LEDs along with a
description of each LED indicator.
Note:
The Power Alarm, Fan Alarm, and the Array
Alarm Status Indicator LEDs are active only when a RAID
board is installed or server management software is in use.
Front System Status Indicator LEDs
LED
Status
Description
Response
DC Power ON/OFF
Off
DC power OFF
None required (normal)
ON (Green)
DC power ON
None required (normal)
Power Alarm
Off
Not active
None required (normal)
ON (Amber)
Failure has occurred in one or more
power supplies (see the "Power Supply
Status Indicators" table DC Power Status
"Amber" that follows.)
Fan Alarm
Off
All fans operating normally
None required (normal)
ON (Amber)
Fan failure
Replace fan in chassis or
replace power supply
Array Alarm
Off
Always OFF unless RAID is installed
None required (normal)
ON (Amber)
RAID Array failure
Replace disk drive with
amber light lite
Power Supply Status Indicator LEDs (Rear Panel)
LED
Status
Description
Response
Power Supply Status
Off
AC Power not available
None required (normal)
ON (Green)
AC Power supplied to power supply
None required (normal)
DC Power Status
Off
No alarms
None required (normal)
(Amber)
AC Power disconnected, power supply
failed, or power supply not installed.
Verify AC power is ON,
reconnect AC power, or
replace power supply,
Summary of Contents for NEAX Express
Page 1: ... S e r v i c e a n d R e f e r e n c e G u i d e NEAX Express ...
Page 2: ...NEC ...
Page 3: ... S e r v i c e a n d R e f e r e n c e G u i d e NEAX Express ...
Page 18: ...xvi Using This Guide NEC ...
Page 38: ...1 20 System Overview ...
Page 82: ...3 30 Configuring Your System ...
Page 136: ...4 54 Disassembly and Reassembly ...
Page 158: ...5 22 Problem Solving ...
Page 164: ...6 6 Illustrated Parts Breakdown ...
Page 165: ...A System Cabling System Cabling Before You Begin Static Precautions Standard Configuration ...
Page 170: ...A 6 System Cabling ...
Page 208: ...C 20 Emergency Management Port ...
Page 209: ...D Platform Event Paging ...
Page 224: ...E 14 Connectors ...
Page 234: ...10 Glossary ...
Page 241: ...xx ...
Page 242: ... 456 01510 000 ...