CHAPTER 3 SYSTEM DATA PROGRAMMING
– 116 –
ND-71503(E) Rev.5.0
9pch3001.fm
DESCRIPTION
DATA
Assign the number of port that is controlled by
the MP built-in FP.
[Series 3200 R6.2 software required]
NOTE 1:
This data can be set to the FP num-
ber of MP built-in FP.
NOTE 2:
Be sure to set every 8 port. If the set-
ting value of the second data cannot
be divided by 8, the value that the re-
mainder is omitted is assigned to the
FP number.
NOTE 3:
Be sure to assign the port number
from 000 consecutively. Do not as-
sign from the middle and also do not
make a blank port. For example,
when using 64 port, the port number
must be 000-064.
•
(1)
(2)
Y=3
00-59: FP No.
000-128 : Number of port (every 8 port)
NOTE 2
NONE : See the table below.
B
CM05
INITIAL
FP No.
Number of Port
00-03
128
(for MP built-in FP)
04-59
0
END
JANUARY/16/2004
REMOTE PIM OVER IP DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC