CHAPTER 3 SYSTEM DATA PROGRAMMING
– 158 –
ND-71503(E) Rev.5.0
9pch3001.fm
Assign the required data to accommodate Legacy Line/Trunk by CM07, CM10, CM14, etc.
NOTE:
When using the 2-line analog trunk (2COT/2LDT/2ODT) to connect to the D
term
IP, the PAD
data for 2-line analog trunk must be set as follows.
If the following data is not set, the D
term
IP will receive a big echo during the communication.
CM35 Y=19 (1) 00-63 (Trunk Route No.)
(2) 6 (3 dB [Transmit/Receive])
DESCRIPTION
DATA
NOTE 3:
When using only PN-8IPLA (IP-PAD) card in the system, follow the initial data setting.
When using PN-8IPLA (IP-PAD) card and PN-32IPLA/PN-32IPLA-A (IP-PAD) card in
the system, you must not set the second data to 02 (Use only IP-PAD channel without
16VCT).
Assign the DTMF signal width on system basis
for PN-8IPLA.
[Series 3300 software required]
•
(1)
(2)
Y=0
106
04-15: 64-240 ms.
(16 ms. increments)
NONE : No data
Assign the DTMF Inter-digit Pause on system
basis for PN-8IPLA.
[Series 3300 software required]
•
(1)
(2)
Y=0
107
01: 64 ms.
02: 80 ms.
03: 96 ms.
04: 128 ms.
05: 160 ms.
06: 192 ms.
07: 240 ms.
NONE : No data
Specify the time until IP network between
main site and remote site is reconnected.
[Series 3300 software required]
•
(1)
(2)
Y=0
108
00-99: 0-99 seconds
(1 second increment)
NONE : No data
L
CM67
CM41
END
SEPTEMBER/15/2004
IP-PAD DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC