CHAPTER 3 SYSTEM DATA PROGRAMMING
– 182 –
ND-71503(E) Rev.5.0
9pch3001.fm
DESCRIPTION
DATA
Provide the Echo Canceller between location
groups with each location number assigned by
CM12 Y=39, 50/CM8A Y=5000-5255/CM0A
Y=09, if required.
[Series 3200 R6.2 software required]
•
(1)
(2)
Y=03
XXZZ
XX: 00-63: Location No. of group
ZZ : 00-63: Location No. of group
00
: Echo Canceller OFF
01
: Echo Canceller ON
NONE : Echo Canceller ON
NOTE 1:
This data setting is valid to the group that is set to “XX” in the first data.
NOTE 2:
When this data is set to the location number assigned by CM0A Y=09, there are conditions
as follows.
• The data setting of CM0A Y=21 (Echo Canceller control for IP-PAD) is invalid when
this data is set.
• When this data is set, the data setting of CM0A Y=22 (NLP control for IP-PAD) is not
required.
Specify the minimum value of jitter buffer be-
tween location groups to each location number
assigned by CM12 Y=39, 50/CM8A Y=5000-
5255/CM0A Y=09.
[Series 3200 R6.2 software required]
NOTE 1:
Assign the value which does not ex-
ceed the maximum value of jitter
buffer set by CM67 Y=05.
NOTE 2:
This data setting is valid to the
group that is set to “XX” in the first
data.
•
(1)
(2)
Y=04
XX ZZ
XX: 00-63: Location No. of group
ZZ : 00-63: Location No. of group
01-30
: 10 ms.-300 ms.
(10 ms. increments)
NONE : 10 ms.
D
CM67
E
JANUARY/16/2004