– C11 –
ND-71503(E) Rev.5.0
9papc001.fm
SETUP THE SYSTEM
After the office data programming in
(
), follow the procedure be-
low. (The two routers should already be working correctly.)
STEP1:
Turn power switch of the Main Site on.
STEP2:
Confirm that the MP in Main Site is working, and turn power switch of the Remote Site on.
– The communication between Main Site and Remote Site starts. (The RX/TX lamp on PZ-
M606-A card lights on.)
STEP3:
Confirm that the office data has been copying from Main Site to Remote Site.
– After 30 seconds, the RUN lamp on MP card at Remote Site flashes at 30 IPM.
STEP4:
Confirm that the office data is backed up in Flash ROM of MP card at Remote Site.
– SYSD lamp on the MP card turns on, and the data back up starts. (It takes two minutes to back
up the office data.)
STEP5:
Confirm that Normal Mode operation starts.
– The MP card in the Remote Site resets itself automatically, and starts Normal Mode operation.
JANUARY/31/2003