CHAPTER 3 SYSTEM DATA PROGRAMMING
– 88 –
ND-71503(E) Rev.5.0
9pch3001.fm
Setting A-law/µ-law
[For PBC]
[Series 3200 R6.2 software required]
DESCRIPTION
DATA
Specify the A-law/µ-law for the main site.
NOTE 1:
When using PN-CP24-A/PN-CP24-
B/PN-CP27-A, set the 2nd data to 3
and set the A-law/µ-law by the SW2-
1.
NOTE 2:
When using PN-CP31-A/PN-CP31-
B, the system is set to µ-law auto-
matically. Set the 2nd data to 0 for
A-law.
NOTE 3:
Set the same value as remote site
(CM04 Y=11-40). You cannot set
both of A-law and µ-law in the same
Remote PIM over IP system.
•
(1)
(2)
Y=10
00
0 : A-law
1 : µ-law
2 : Not used
3 : Depends on the SW2-1 on PN-CP24-
A/PN-CP24-B/PN-CP27-A or the Key
ROM (SP-3722 IPS KYUS PROG-
A1) on PN-CP31-A/PN-CP31-B
START
CM04
END
SEPTEMBER/15/2004
BASIC DATA SETTING