CHAPTER 3 SYSTEM DATA PROGRAMMING
– 94 –
ND-71503(E) Rev.5.0
9pch3001.fm
VLAN Data Assignment
[Series 3100 software required]
NOTE 1:
The system supports only Tag VLAN.
NOTE 2:
Switching HUB that supports VLAN is required to provide the VLAN function.
DESCRIPTION
DATA
Provide the VLAN with the system.
NOTE:
Clear the IP Address and the Subnet
Mask for the system that have been
set by CM0B Y=00>00, 01.
•
(1)
(2)
Y=02
00
0 : To provide
1 : Not provided
Specify the priority of the VLAN.
NOTE:
The higher number has higher pri-
ority.
•
(1)
(2)
Y=02
01
0-7 : Priority 0-7
NOTE
Assign the VLAN ID to the system.
NOTE 1:
One VLAN ID can be set per system.
NOTE 2:
VLAN ID 0 is not available.
•
(1)
(2)
Y=02
02
0001-4094: VLAN ID 1-4094
NOTE 2
NONE : No data
Assign the IP Address for the VLAN.
NOTE:
Clear the IP Address and the Subnet
Mask for the system that have been
set by CM0B Y=00>00, 01.
•
(1)
(2)
Y=02
03
000000000000-255255255255:
IP Address for the VLAN
NONE : No data
Assign the Subnet Mask for the VLAN.
•
(1)
(2)
Y=02
04
000000000000-255255255255:
Subnet Mask for the VLAN
NONE : No data
START
CM0B
INITIAL
INITIAL
INITIAL
INITIAL
INITIAL
A
JANUARY/31/2003
BASIC DATA SETTING
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn