CHAPTER 3 SYSTEM DATA PROGRAMMING
– 104 –
ND-71503(E) Rev.5.0
9pch3001.fm
Remote PIM over IP VLAN Data Assignment
(1) VLAN Data Assignment for Main Site
See
(2) VLAN Data Assignment for Remote Site
[Series 3200 R6.2 software required]
DESCRIPTION
DATA
Provide the VLAN with the remote site.
•
(1)
(2)
Y=31-60 (Remote Site No. 01-30)
30
0 : To provide
1 : Not provided
Specify the priority of the VLAN.
NOTE:
The higher number has higher pri-
ority.
•
(1)
(2)
Y=31-60 (Remote Site No. 01-30)
31
0-7 : Priority 0-7
NOTE
Assign the VLAN ID to the remote site.
NOTE 1:
One VLAN ID can be set per remote
site.
NOTE 2:
VLAN ID 0 is not available.
NOTE 3:
Clear the IP Address and the Subnet
Mask for the remote site that have
been set by CM0B Y=31-60>00, 01.
•
(1)
(2)
Y=31-60 (Remote Site No. 01-30)
32
0001-4094: VLAN ID 1-4094
NOTE 2
NONE
: No data