CHAPTER 3 SYSTEM DATA PROGRAMMING
– 128 –
ND-71503(E) Rev.5.0
9pch3001.fm
DESCRIPTION
DATA
Assign a Prime Line to the D
term
IP.
(1)
(2)
X-XXXXXXXX: My Line No.
X-XXXXXXXX: Station No.
Assign the port number of the PROTIMS port
(which is NEC original UDP port) to each Vir-
tual FP number.
NOTE 1:
Follow the initial data setting usual-
ly.
NOTE 2:
64 ports from the UDP Base Port
number you set are assigned to the
Virtual FP number. If no data is set,
the UDP port number is assigned to
No. 50000-53776.
NOTE 3:
One port from the UDP Base Port
number you set are assigned to the
Virtual FP number automatically,
when the second data of CM05 Y=6
is set to “1” (Remote Site).
NOTE 4:
One UDP port is required to a
D
term
IP. Assign the necessary num-
ber of UDP port to the Virtual FP
number suitable for the number of
D
term
IPs.
•
(1)
(2)
Y=10
00-59: Virtual FP No.
01024-65534: UDP Base Port No.
NONE
: See below.
Virtual FP No.
UDP Base Port No.
00
50000
01
50064
02
50128
03
50192
:
:
:
:
59
53776
Assign the port number of the Registration Ad-
mission Status (RAS) port which is NEC orig-
inal UDP port for System-based DRS.
NOTE:
Follow the initial data setting usual-
ly.
•
(1)
(2)
Y=10
60
01024-65535: UDP Port No. 1024-
65535
00000-01023: UDP Port No. 3456
NONE
: UDP Port No. 3456
A
CM93
CM0B
INITIAL
INITIAL
END
SEPTEMBER/15/2004
D
term
IP DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn