CHAPTER 3 SYSTEM DATA PROGRAMMING
– 146 –
ND-71503(E) Rev.5.0
9pch3001.fm
IP-PAD DATA ASSIGNMENT
In addition to the system constitution data for IP-PAD, do the following programming.
The IP-PAD is required for the following connections.
– D
term
IP-to-Legacy terminal connection
– D
term
IP-to-Public Network/Tie Line Network connection
– External hold tone connection
– Conference Trunk (CFT) connection
– Digital Announcement Trunk (DAT) connection
DESCRIPTION
DATA
Define the LAN Interface of the IP-PAD card.
NOTE 1:
Maximum 8 LAN Interface number
can be assigned for IP-PAD cards.
Use the LAN Interface number 00-
15.
NOTE 2:
In the Remote PIM over IP system,
maximum 32 LAN Interface number
can be assigned for IP-PAD cards.
LAN Interface number 00-31 can be
used.
•
(1)
(2)
Y=00
00-31: LAN Interface No.
NOTE 1
,
NOTE 2
XXZ
XX: FP No. 00-59 which accommodates
the IP-PAD
Z : IP-PAD No. 0-3
NOTE 3
NONE : No data
NOTE 3:
Set the IP-PAD serial number according to the accommodated PIM and slot as follows.
[For PN-32IPLA/PN-32IPLA-A]
• When accommodated in odd numbered PIM (PIM1/3/5/7)
• When accommodated in even numbered PIM (PIM0/2/4/6)
START
CM0A
IP-PAD INITIAL
VM
LT
0
0
LT
0
1
LT
0
2
LT
0
3
LT
0
4
LT
0
5
LT
0
6
LT
0
7
LT
0
8
LT
0
9
LT
1
0
LT
11
PFT
PIM
1/3/5/7
IP-
PAD
No. 2
IP-
PAD
No. 3
VM
LT
0
0
LT
0
1
LT
0
2
LT
0
3
LT
0
4
LT
0
5
LT
0
6
LT
0
7
LT
0
8
LT
0
9
LT
1
0
LT
11
MP12/FP12
PFT
PIM
0/2/4/6
IP-
PAD
No. 0
IP-
PAD
No. 1
A