Chapter 3 Terminals
D
term
Series III
NEAX2000 IVS
2
General Description
NDA-24293, Issue 2
Page 25
Line Conditions of
Each D
term
Series III Terminal
The cable length between the DLC card and terminal varies depending on the type of
terminal. This table shows the line conditions of each D
term
and DSS/BLF Console.
*The value in brackets [ ] shows the cable length when local power is supplied.
Note 1:
When using PN-8DLCL or PN-8DLCP card, the long-line function is not available, even if D
term
is
equipped with Long Line Adapter.
Note 2:
The DSS/BLF Console requires local AC/DC power supply.
Table 3-1 Line Conditions of Each D
term
Series III Terminal
TERMINAL TYPE
CARD TYPE
CABLE LENGTH*
(CABLE 0.5
φφφφ
/24 AWG)
REMARKS
D
term
Series III (8 button)
PN-8DLCL/8DLCP
(STANDARD)
984 ft. (300 m)
PN-4DLCM/4DLCQ
(STANDARD)
984 ft. (300 m)
[3937 ft. (1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft. (850 m)
[3937 ft. (1200 m)]
D
term
Series III
(16 button)
PN-8DLCL/8DLCP
(STANDARD)
492 ft. (150 m)
PN-4DLCM/4DLCQ
(STANDARD)
492 ft. (150 m)
[3937 ft. (1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft. (850 m)
[3937 ft. (1200 m)]
D
term
Series III
(24 button)
PN-8DLCL/8DLCP
(STANDARD)
492 ft. (150 m)
PN-4DLCM/4DLCQ
(STANDARD)
492 ft. (150 m)
[3937 ft. (1200 m)]
PN-2DLCB/2DLCN
(LONG)
2788 ft. (850 m)
[3937 ft. (1200 m)]
DSS/BLF Console
PN-8DLCL/8DLCP
(STANDARD)
984 ft. (300 m)
PN-4DLCM/4DLCQ
(STANDARD)
984 ft. (300 m)
PN-2DLCB/2DLCN
(LONG)
2788 ft. (850 m)