background image

 
 

 
 

© NEC Corporation 2016 

10 

0xa 

0x104 

Caution 

ASR Timer Failure 

0xa 

0x121 

Critical 

A Critical Error occurred prior to this power-up. 

0xa 

0x218 

Critical 

DIMM Initialization Error - All DIMMs are mapped out due to 
memory errors except for one to allow the system to boot. 
Additional errors may be present on the remaining DIMM. 
System is booting in a degraded state.   

0xa 

0x224 

Caution 

Power Fault Detected - FlexLOM %1 

0xa 

0x225 

Caution 

Power Fault Detected-Mezzanine %1. 

0xa 

0x226 

Caution 

Power Fault Detected - Embedded Storage Controller %1. 

0xa 

0x268 

Caution 

UEFI Non-Volatile Variable Store Corruption Detected. If enabled, 
Secure Boot security settings may be lost. 

0xa 

0x284 

Critical 

DIMM Failure - Uncorrectable Memory Error - %1 %2 Dimm %3   

0xa 

0x312 

Caution 

%1 %2 Failure - Communication with the battery failed. Its 
output may not be enabled. 

0xa 

0x313 

Caution 

%1 %2 Failure - Battery Shutdown Event Code: 0x%3. 

0xa 

0x315 

Critical 

An uncorrectable memory error was detected prior to this system 
boot. 

0xa 

0x323 

Caution 

%1 Dual microSD Device Error - The microSD card in Slot %2 has 
failed. 

0xa 

0x324 

Critical 

%1 Dual microSD Device Error - Both microSD cards have failed. 

0xa 

0x326 

Critical 

%1 Dual microSD Device Error - The microSD card in Slot %2 has 
failed. A microSD card is not installed in Slot %3. 

0xa 

0x328 

Information 

Power Management Controller Firmware Error - The firmware is 
in Recovery Mode. 

0xa 

0x329 

Information 

Power Management Controller FW Error - Unable to 
communicate with the FW. 

0xa 

0x410 

Caution 

Innovation Engine Error - The Innovation Engine is not operating 

properly.    (Error Code %1).

 

0xa 

0x411 

Critical 

Innovation Engine Error - The Innovation Engine is operating in 
recovery mode. 

0xa 

0x414 

Caution 

Server Platform Services Firmware Error - The SPS Firmware is 

not operating properly. (Error Code %1).

 

0xa 

0x433 

Critical 

Scalable Persistent Memory backup device failure on Box %1 
Bay %2. Persistent data may have been lost. 

Summary of Contents for NEC Express5800 Series

Page 1: ...NEC Express5800 iLO Embedded Server Notice for Express Report Service MG Revision 1 0 Nov 22 2017 NEC Corporation...

Page 2: ...rence Sites 4 Words and Term 4 Revision History 4 1 Introduction 5 2 About NEC Express Report Service 6 3 NEC iLO IML SNMP Trap List 7 4 Precautions for Report Target Events 9 4 1 Events which doesn t...

Page 3: ...er Corporation name and trade name are trademarks or registered trademarks Cautions Unauthorized copying of all or part of this manual is prohibited The contents of this manual may change in the futur...

Page 4: ...service using the error information of the server from iLO using Express Report Service MG software NEC ESMPRO ServerManager Server management software It enables the integrative management of multip...

Page 5: ...orporation 2016 5 1 Introduction This document describes the notice of NEC Express Report Service MG for NEC Express5800 Servers which has iLO on its mother board Please check the NEC iLO IML SNMP Tra...

Page 6: ...ze NEC Express Report Service shown below NEC Express Report Service Agent software NEC ESMPRO ServerAgentService detects error information of the server and report to the Maintenance Company through...

Page 7: ...Trap List NEC iLO IML SNMP Trap List is a list of IML and its SNMP trap information for NEC Express5800 iLO Embedded Servers Occurrence of each events is depends on the model or configuration of the...

Page 8: ...e sent from NEC ESMPRO ServerAgentService to NEC Service Center or not SNMP Trap Information Express Report Service MG Shows the information whether the item will be sent to NEC Service Center with Ex...

Page 9: ...Sensor 2 Location 3 Temperature 4 0x2 0x2a Critical 1 Storage System Overheating 2Slot 3 Temperature Sensor 4 Location 5 Temperature 6 0x2 0x2b Critical 1 Overheating Temperature Sensor 2 Location 3 T...

Page 10: ...Failure Battery Shutdown Event Code 0x 3 0xa 0x315 Critical An uncorrectable memory error was detected prior to this system boot 0xa 0x323 Caution 1 Dual microSD Device Error The microSD card in Slot...

Page 11: ...One or more configuration changes since the last boot may not have taken affect 0xa 0x454 Caution NVDIMM Error Persistent Memory Address Range Scrub error threshold exceeded on Processor 1 DIMM 2 SN 3...

Page 12: ...te 0xa 0x2408 Caution Slot 1 Error Firmware image recovery not successful 0xa 0x2410 Caution Slot 1 Error Controller I O timeout failure 0xa 0x2416 Caution 1 Error Controller firmware not ready 0xb 0x...

Page 13: ...al KTI initialization error has been detected 1 Major Code 2 Minor Code 3 0x32 0x221 Critical Unknown Initialization Error The system has experienced a fatal initialization error 1 Major Code 2 Minor...

Page 14: ...image could not be authenticated 0x32 0x462 Critical Uncorrectable Memory Error Threshold Exceeded 1 2 DIMM 3 The DIMM is mapped out and is currently not available 0x32 0x3011 Critical MemBIST MEMTEST...

Page 15: ...CODE 0x1a FAN Failure Report is required 6035 Report Target SNMP Trap ID 6035 became and report target of Express Report Service MG because FAN Failure IML is an report target of Express Report Servi...

Page 16: ...NEC Corporation 2016 16 End...