D-35
(7)
Leading Edge Tilt Adjustment
1. Print the test pattern.
2. Draw lines 100 mm (A and B) from the center of
the test pattern, as shown in the illustration.
1382D007AA
A
B
100 mm
100 mm
3. Load the test pattern into the Automatic Docu-
ment Feeder, and then print five single-sided cop-
ies.
NOTE
•
The test pattern should be positioned vertically.
1382U027AA
4. Measure the lengths a and b on the copies of the
test pattern and, if there is a large shift, adjust it
according to the following procedure.
Standard values of a and b = ± 1.0 mm
1382D008AA
a
b