3.12 Additional FC Port
(1) FC connector (for connection of host bus adapter) (HF1)
The FC connector is used to connect the host system with the disk array unit.
See Section 5 "CONNECTION OF DISK ARRAY UNIT" for the cable connection.
(2) LINKUP LED (HL1)
The LINKUP LED lights green when the FC connector (FC port) becomes operable
(Link UP).
The LED is off during the self-test and initialization immediately after the power is
turned on.
(3) HOST-2G LED (green)
The HOST-2G LED lights green while the host bus adapter interface is operating at
2Gbps. The LED is off while it is operating at 1Gbps.
(4) AL-PA
switch
The AL-PA switch sets the address of the disk array unit as a FibreChannel device in
the host FC loop.
Set an AL-PA so that it will be different from the AL-PAs of other FibreChannel
devices in the same host FC loop.
When installing or replacing the additional FC card into the controller,
push it as far as it will go and then secure it with the screws.
Incorrect insertion may cause malfunction.
(5) HOST-2G LED (H2G)
(6) AL-PA switch
(2) FC connector (for connection of host bus adapter)
(3) LINKUP LED (HL1)