Base Module
855-900547-200 2-24
•
Possible Events (including operator entries) and System Responses
Event System
Response
Login account or password was wrong.
The login prompt reappears after the message
“incorrect” comes on.
Login account or password rejected 3
times consecutively.
The console is disconnected.
No operations made for 5 minutes on the
login account or password prompt screen.
The console is disconnected after the message
“timeout” appears.
A letter not specified in the menu was
entered.
The menu reopens.
No operation made for 5 minutes on the
Menu screen.
The console is disconnected after the message
“timeout” appears.
The menu became invalid after iSP
master assignment has been changed.
The invalid menu or prompt is not identified
immediately.
If you make a selection in the invalid menu, that
selection is rejected and a new menu opens.
A value from 0 to 7 selected.
(valid only on the master iSP)
OS (BIOS) Serial Console Redirection is chosen.
S selected.
(valid regardless of master/backup
assignment)
SP Command Console is chosen.
V selected.
(valid only on the master iSP)
Virtual SOP is chosen.
E selected.
The current console connection is disconnected.
DISCONNECTALL selected.
All TCP connections to the iSP other than the
current console connection are disconnected and
the screen is forcibly returned to the Main Menu
in case of serial connection console.
This emergency action might be needed if
console operation is prohibited when actually
disconnected TCP connections remain alive
under the iSP management due to client’s illegal
access.
The number of simultaneous connections
allowable for the selected mode was
exceeded.
The screen returns to the Main Menu after
showing a message “N connections to the
selected mode are already established. Try it
later.”
2.4.2. Note
While in serial or OS console connection, characters that are shown on the console screen may
be disturbed due to redirection made in a half way of ESC sequence.