19

2017-06-06    #:126-9191-2   (2019-05-03)

2c

ENG - When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum 

compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks 

must meet ASTM C-90 specifications and have a minimum nominal width of 8". Do not drill into mortar joints! 

Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. It is 

suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid 

breaking out the back of the hole when entering a void or cavity. Never attach concrete expansion anchors to 

concrete or cinder block covered with plaster, drywall or other finishing material.

 WARNING

FRN - Lors de l’installation de supports muraux Peerless sur un mur en béton, celui-ci doit avoir au moins 8 po 

(20 cm) d'épaisseur et une résistance à la compression d'au moins 2 000 psi. Lors de l’installation de supports 

muraux Peerless sur un mur en blocs de béton, ceux-ci doivent respecter les normes ASTM C-90 et avoir une 

épaisseur nominale d'au moins 8 po (20 cm). Ne percez pas dans les joints de mortier! Veillez à installer le 

support dans une partie solide du bloc, généralement à un minimum de 1 po (25 mm) à partir du côté du bloc. Il 

est conseillé de percer le trou à l’aide une perceuse électrique standard à vitesse basse plutôt que d’un marteau 

perforateur afin d’éviter de briser le fond du trou lorsque vous entrez dans un vide ou une cavité. Ne fixez jamais 

des chevilles à expansion pour béton à du béton ou du bloc de béton recouvert d’une couche de plâtre, d’une 

cloison sèche ou de tout autre matériau de finition.

 ADVERTISSEMENT

ESP - Cuando vaya a instalar soportes de pared de Peerless en paredes de concreto, las paredes tienen que 

tener, por lo menos, 8" de grosor con una resistencia a la compresión de 2000 psi como mínimo. Cuando vaya a 

instalar soportes de pared de Peerless en paredes de hormigón de escorias, los bloques tienen que cumplir las 

especificaciones de ASTM C-90 y tener un ancho mínimo de 8". ¡No taladre en juntas de argamasa! Asegúrese 

de hacer la instalación en la parte sólida del bloque, por lo general, a un mínimo de 1" (25 mm) del extremo del 

bloque. Se sugiere utilizar un taladro eléctrico convencional a baja velocidad para hacer los agujeros en vez de 

un taladro percutor para no perforar el fondo de los agujeros al entrar en un vacío o una cavidad. Nunca fije los 

anclajes de expansión para concreto a superficies de concreto o de bloques de hormigón de escorias recubiertas 

con yeso, yeso-cartón u otro material de acabado.

 ADVERTENCIA

DEU - Werden Peerless-Wandhalter an einer Betonwand angebracht, so muss deren Dicke mindestens 203 

mm (8 Zoll) und ihre Druckfestigkeit mindestens 13,8 N/mm2 (2000 psi) betragen. Bei der Anbringung von 

Peerless-Wandhaltern an einer Porenbetonsteinwand müssen die Porenbetonsteine den Spezifikationen der 

ASTM C-90 entsprechen und eine Mindestnennbreite von 203 mm (8 Zoll) aufweisen. Bohren Sie nicht in 

Mörtelfugen! Achten Sie darauf, dass die Anbringung an einem massiven Teil des Blocks erfolgt, im Allgemeinen 

mindestens 25 mm (1 Zoll) von der Blockseite entfernt. Wir empfehlen, zum Bohren des Lochs anstelle eines 

Schlagbohrers einen standardmäßigen Elektrobohrer bei niedriger Einstellung zu verwenden, um zu verhindern, 

dass die Bohrungsrückseite beim Eintritt in einen Leer- oder Hohlraum ausbricht. Betonspreizdübel dürfen auf 

keinen Fall an Beton oder Porenbetonstein befestigt werden, die mit Verputz, Trockenwand- oder anderem 

Deckschichtmaterial bedeckt sind.

 ACHTUNG

 WAARSCHUWING

NEL - Als de Peerless-wandbevestiging op een betonnen muur wordt geïnstalleerd, moet deze muur een dikte 

van ten minste 20 cm hebben en een druksterkte van ten minste 2000 psi. Als de Peerless-wandbevestiging op 

een muur van B2-blokken wordt geïnstalleerd, moeten deze B2-blokken voldoen aan de ASTM C-90-specificaties 

en een breedte hebben van ten minste 20 cm. Niet in de mortelvoegen boren! De bevestigingsschroeven 

moeten in een massief deel van het blok grijpen (gewoonlijk ten minste 2,5 cm vanaf de zijkant van het blok). 

Het verdient aanbeveling om voor het boren van het gat een standaard elektrische boor te gebruiken op lage 

snelheid in plaats van een boorhamer; dit om te voorkomen dat u de achterkant van het boorgat beschadigt, 

mocht u een holte treffen. Gebruik nooit expansie-ankers voor beton bij installatie op een betonnen muur of een 

muur van B2-blokken bedekt met gips, gipsplaat of ander afwerkingsmateriaal.

Summary of Contents for PD04VW QR 46 55

Page 1: ...1 2017 06 06 126 9191 2 2019 05 03 PD04VW QR 46 55 46 60 117 152 cm 125 lb 57 kg MAX ENG ESP FRN DEU NEL ITL E SLK POR T R...

Page 2: ...la capacit de charge maximale Pour lever et positionner l quipement en toute s curit faites vous toujours aider par une autre personne ou utilisez un dispositif de levage m canique Ce produit est con...

Page 3: ...n yard m al n z veya mekanik bir kald rma donan m kullan n z Bu r n yaln zca i mek nlarda kullan lmak zere imal edilmi tir Bu r n n d mek nda kullan lmas r n ar zalar na veya yaralanmalara sebep olabi...

Page 4: ...mo tr s voltas completas e ajustar se no local Vidalar en az tam d n yapmal ve s k oturmal d r ENG ESP FRN DEU NEL ITL E SLK POR T R Display center Centro de la pantalla Centre de l cran Bildschirmmit...

Page 5: ...ektes Festziehen der Schrauben Ziehen Sie die Schrauben fest bis der Schraubenkopf Kontakt hat und dann um eine weitere 1 2 Umdrehung Ziehen Sie die Schrauben nicht zu fest an Ga als volgt te werk om...

Page 6: ...esentadas em baixo Par alar Ba lamadan nce a a da g sterilen b t n par alar n elinizde oldu undan emin olun ENG ESP FRN DEU NEL ITL E SLK POR T R B 1 left adaptor bracket C 1 right adaptor bracket A 1...

Page 7: ...6 126 9191 2 2019 05 03 N 8 spacer M 8 M6 M8 washer I 4 M6 x 12mm J 4 M6 x 25mm K 4 M8 x 12mm L 4 M8 x 25mm 20 1128 520 9571 520 1031 O 4 shoulder washer Q 4 M8 x 15mm R 1 4mm allen wrench P 2 600mm a...

Page 8: ...e samostatn S rie DS VWRS Pred va sa samostatne S rie DS VWRS Vendidas em separado DS VWRS serisi Ayr ca sat l r ENG ESP FRN DEU NEL ITL E SLK POR T R ENG ESP FRN DEU NEL ITL E SLK POR T R Optional Re...

Page 9: ...nu kvarobet nov ho bloku Bet o Bloco de cimento Beton Brikete ENG ESP FRN DEU NEL ITL E SLK POR T R 2a Plywood Madera contrachapada Contreplaqu Sperrholz Multiplex Legno compensato P ekli ka Preglejk...

Page 10: ...ique se os parafusos prisioneiros de madeira t m ao menos 2 x 4 de di metro nominal e a madeira compensada no m nimo da Classe BC 1 2 13mm de espessura O contraplacado deve ser coberto com uma placa d...

Page 11: ...ecr Y Ekran geni li i ENG ESP FRN DEU NEL ITL E SLK POR T R 2a 2 Locate display center for bottom left display Localice el centro de la pantalla inferior izquierda Localisez le centre de l cran inf ri...

Page 12: ...oles on plywood must be minimum Grade BC 1 2 13mm thick Nivele la placa de pared Marque los puntos de los agujeros de montaje en el contrachapado tiene que ser de Grado BC como m nimo de un grosor de...

Page 13: ...von 13 mm bzw 1 2 Zoll verf gen Zorg dat de wandplaat waterpas is Teken de montagegaten op de multiplex dit moet minimaal 13 mm dik zijn Livellare la piastra da parete Contrassegnare i fori di montag...

Page 14: ...o nosnej plochy minim lna vy adovan h bka je 64mm 2 5 Perfure os furos de montagem na superf cie de apoio 64mm de profundidade m nima necess ria Montaj deliklerini destekleyici y zeye delin 64mm 2 5 i...

Page 15: ...ge nstalleerd op gipsplaat met een dikte van meer dan 15 88 mm Als er meerdere schermen op een horizontale rij op een muur met houten balken worden ge nstalleerd moet de muur worden versterkt met een...

Page 16: ...ecr Y Ekran geni li i ENG ESP FRN DEU NEL ITL E SLK POR T R 2b 2 Locate display center for bottom left display Localice el centro de la pantalla inferior izquierda Localisez le centre de l cran inf ri...

Page 17: ...DEU NEL ITL E SLK POR T R Level wallplate Mark mounting holes on stud center lines Marque los orificios de montaje en las l neas centrales del montante Marquez les trous de fixation le long de la lign...

Page 18: ...minimum derinlik gereklidir ENG ESP FRN DEU NEL ITL E SLK POR T R 5 32 4mm Mounting hole must center on stud El orificio debe quedar centrado en el montante Le trou doit tre centr sur le montant Das...

Page 19: ...e s lida del bloque por lo general a un m nimo de 1 25 mm del extremo del bloque Se sugiere utilizar un taladro el ctrico convencional a baja velocidad para hacer los agujeros en vez de un taladro per...

Page 20: ...e le specifiche ASTM C 90 ed avere una larghezza nominale minima di 20 cm Non trapanare sulle giunture di malta Accertarsi che il montaggio avvenga su una parte solida del mattone di solito ad almeno...

Page 21: ...displeja pre av spodn displej Coloque o centro do ecr esquerdo inferior Sol alttaki ekran n merkezini belirleyiniz ENG ESP FRN DEU NEL ITL E SLK POR T R 2c 1 X X Display height X altura de la pantalla...

Page 22: ...or montagegaten in het ondersteunende oppervlak met een diepte van ten minste 64mm Trapanare I fori di sostegno nella superficie di supporto profondit minima richiesta 64mm 2 5 Vyvrtejte mont n otvory...

Page 23: ...N M ENG ESP FRN DEU NEL ITL E SLK POR T R Peerless model ACC234 sold separately 800 865 2112 Modelo ACC234 vendido por separado 800 865 2112 Mod le Peerless ACC234 vendu s par ment 800 865 2112 Peerl...

Page 24: ...ts bevinden alvorens door te gaan Prima di procedere verificare che le staffe di adattamento siano nella stessa posizione P ed zah jen m zkontrolujte jestli jsou konzoly adapt ru nomin ln Predt m ako...

Page 25: ...DEU NEL ITL E SLK POR T R Remove quite retirez entfernen verwijderen rimuovere odstranit odstr ni remova kart n Optional security screws Tornillo de seguridad opcional para trabar el soporte cerrado V...

Page 26: ...ptional Uso de espaciadores opcional Facultatif utilisation d entretoises Fakultativ Verwendung von Abstandhaltern Facultatief gebruik van tussenringen Uso opzionale di distanziatori Voliteln pou it r...

Page 27: ...27 2017 06 06 126 9191 2 2019 05 03 4b 1 R Q 4 P 2 P 2 Q 4 C C B B...

Page 28: ...se of spacers is optional Uso de espaciadores opcional Facultatif utilisation d entretoises Fakultativ Verwendung von Abstandhaltern Facultatief gebruik van tussenringen Uso opzionale di distanziatori...

Page 29: ...RN DEU NEL ITL E SLK POR T R Tighten Apretar Serrer Anziehen Aandraaien Stringere Ut hn te Utiahnite Apertar S kmak B C H 5 1 5 2 ENG ESP FRN DEU NEL ITL E SLK POR T R Remove quite retirez entfernen v...

Page 30: ...SLK POR T R Optional cable management Opcional manejo de cables Facultatif gestion des c bles Fakultativ Kabelf hrung Facultatief kabelbeheer Opzionale gestione dei cavi Voliteln veden kabel Volite n...

Page 31: ...lay n ENG ESP FRN DEU NEL ITL E SLK POR T R Optional adjustment Opcional ajuste Facultatif r glage Fakultativ instellung Facultatief aanpassing Opzionale regolazionei Voliteln nastaven Volite n nastav...

Page 32: ...32 2017 06 06 126 9191 2 2019 05 03 9 2...

Page 33: ...9 3 ENG ESP FRN DEU NEL ITL E SLK POR T R Optional adjustment Opcional ajuste Facultatif r glage Fakultativ instellung Facultatief aanpassing Opzionale regolazionei Voliteln nastaven Volite n nastaven...

Page 34: ...sluiten Allungare completamente solo per la manutenzione Chiudere dopo la manutenzione Pln rozsah pouze pro servisn ely Po proveden servisn ho z sahu uzav t Pred te plne len s cie om servisovania Po...

Page 35: ...35 2017 06 06 126 9191 2 2019 05 03 10 3 B C ENG ESP FRN DEU NEL ITL E SLK POR T R Loosen Afloje Desserrez L sen Losdraaien Allentare Uvolnit Uvo ni Desaperte Gev etin...

Page 36: ...e et la limitation ci dessus peut donc ne pas vous tre applicable Cette garantie ne couvre pas les dommages caus s par a un entretien ou des r parations effectu s par l acheteur ou une personne non au...

Page 37: ...i manutenzione o riparazione b non utilizzo dell imballaggio corretto in occasione di restituzione del prodotto c installazione scorretta o inosservanza delle istruzioni o delle avvertenze fornite dal...

Page 38: ...nte ou por uma pessoa n o autorizada pela Peerless para a realiza o de tais servi os e repara es b n o utiliza o da embalagem adequada para a devolu o do produto c instala o incorrecta ou n o observa...

Page 39: ...derirken d zg n paketleme yap lmamas c yanl kurulum yap lmas veya r n kurarken kullan rken veya depo ederken Peerless in talimatlar na veya uyar lar na uygun davran lmamas d nc taraflardan veya zorlay...

Page 40: ...Industries Inc Peerless AV de Mexico Ave de las Industrias 413 Parque Industrial Escobedo Escobedo N L Mexico 66050 Servicio al Cliente 01 800 849 65 77 www peerless av com 2018 Peerless Industries In...

Reviews: