English
English-25
RS-232C
- continued
3) Control sequence
1) Th
e command from a computer to the Plasma monitor will take 400ms.
2) Th
e Plasma monitor will send a return command 400ms* aft er it has received
an encode. If the command is not received correctly,
the Plasma monitor will not send the return command.
3) Th
e personal computer checks the command and confi rms if the
command which has been sent has been executed or not.
4) Th
is Plasma monitor sends various codes other than the return code. When
sending a control sequence via RS-232C, other codes from personal
computers will be ignored.
*Th
e sending time of the return command may be delayed depending on the
monitor’s current activity (changing of the input signal, etc.).
[Example] Turn the power ON. (
'
'
is for ASCII code)
Sending commands
from the PC etc.
Status code from
Plasma monitor
Meaning
30 30 21 0D
'0' '0' '!' '
'
Command for
POWER ON
30 30 21 0D
'0' '0' '!' '
'
Command received
(Command echo back)
4) Operation commands
Operation commands execute the basic operation setting of this Plasma
monitor. It may not operate when changing the signal:
Operation
ASCII
HEX
POWER ON
!
21h
POWER OFF
"
22h
INPUT VIDEO1
_v1
5Fh 76h 31h
INPUT S-VIDEO
_v3
5Fh 76h 33h
INPUT DVD/HD1
_v2
5Fh 76h 32h
INPUT DVD/HD2
_v5
5Fh 76h 35h
INPUT DVD/HD3
_h1
5Fh 68h 31h
INPUT SCART2
_v6
5Fh 76h 36h
INPUT VGA
_r2
5Fh 72h 32h
INPUT DVI
_r1
5Fh 72h 31h
POWER OFF command should not be used less than 1 minute aft er the power is
turned on.
POWER ON command should not be used less than 1 minute aft er the power is
turned off .
•
•