- 49 -
Removal Procedure
Remove the FC Switch Module from a Blade Enclosure (SIGMABLADE) according to the procedure
described below.
1.
Remove the FC cable connected to the FC Switch Module.
Remove the FC cable with close attention. Removing the FC cable with
excess force may cause the mating connector on the FC cable to be
damaged or the cable to be disconnected.
Always put caps on the connectors of the removed FC cable. If a FC cable
is left without caps put on the connectors, a fault may occur in its reuse due
to dust adhering on the connectors.
2.
Remove the SFP module installed on the FC Switch Module.
See Section 4-2 for the SFP module removal procedure.
Always put dust-proof cover on the removed SFP module. If an SFP module
is left without dust-proof cover, a fault may occur on its reuse due to dust
adhering on the module.
3.
Unlock the stopper on the FC Switch Module to unlatch the ejector.
Press the stopper lightly in the right direction to unlock the stopper. Then the
ejector is unlatched.