Chapter 2 Message List
290
iSM13556: SCSI I/O error has occurred.
[Classification] ERROR
[Explanation]
SCSI I/O error has occurred.
[Measures]
A failure may be occurring in connection with disk array. Check status of
FC-AL connection and then retry processing. If no problems are found in status
of FC-AL connection, check that a special file or physical disk exists for the
specified volume, and access is permitted. Then retry processing.
iSM13557: SCSI open has failed.
[Classification] ERROR
[Explanation]
SCSI open error occurred.
[Measures]
Check that the user with the access right to the volume exists or that the disk
number corresponding to the specified volume exists, and execute it again.
iSM13558: SCSI close has failed.
[Classification] ERROR
[Explanation]
SCSI close error occurred.
[Measures]
Check that the user with the access right to the volume exists or that the disk
number corresponding to the specified volume exists, and execute it again.
iSM13559: Parameter error occurred.
[Classification] ERROR
[Explanation]
Parameter error occurred in the internal processing.
[Measures]
Collect information on operation trace
Summary of Contents for Storage Manager Messages
Page 1: ...NEC Storage Manager Messages Handbook ...
Page 4: ......
Page 422: ...Appendix A Message Output Destination List 417 Output Not output when the default is selected ...
Page 426: ...Appendix A Message Output Destination List 421 Output Not output when the default is selected ...
Page 434: ...Appendix A Message Output Destination List 429 Output Not output when the default is selected ...
Page 436: ...Appendix A Message Output Destination List 431 Output Not output when the default is selected ...
Page 450: ...Appendix A Message Output Destination List 445 Output Not output when the default is selected ...
Page 454: ...Appendix A Message Output Destination List 449 Output Not output when the default is selected ...
Page 468: ...Appendix A Message Output Destination List 463 Output Not output when the default is selected ...