3-711
NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE TITLE:
REMOTE PROGRAM DOWNLOAD INFORMATION READ,
FAILOVER INFORMATION READ
FB
NOTE 1:
When the first data is set to “XX16”, the meanings of readout data is as follows.
- Readout data “00”
: Standard CPU (Normal mode)
- Readout data “10”
: CPU for Remote Unit only (Normal mode)
- Readout data “NONE”: Disconnected/Survival mode
NOTE 2:
When PCPro is connected to the Main Unit, type of CPU which is controlled under normal
mode is confirmed by this command. When CPU which is disconnected to the system or con-
trolled under survival mode, type of CPU is not confirmed and “NONE” is displayed as
readout data.
NOTE 3:
When the first data is set to “XX17”, the meanings of readout data is as follows.
- Readout data “0”
: CPU0
- Readout data “1”
: CPU1
- Readout data “NONE”: Not provided (Accommodated in 1U module)
Continued on next page
Y
1ST DATA
READOUT DATA
No.
MEANING
DATA
MEANING
DATA
MEANING
10
Remote Program
Information Read
(For Stand by
CPU)
[8300R4]
01 bb
bb : CPU program information
02 : SC No.
03 : Official Version
04 : Official Revision
06 : Year, Month, Day
17 : CPU0/CPU1 recognition
NOTE 3
22 : Upgraded side of CPU blade: SC No.
23 : Upgraded side of CPU blade: Official
Version
24 : Upgraded side of CPU blade: Official
Revision
26 : Upgraded side of CPU blade: Year,
Month, Day
42 : Outdated side of CPU blade: SC No.
43 : Outdated side of CPU blade: Official
Version
44 : Outdated side of CPU blade: Official
Revision
46 : Outdated side of CPU blade: Year,
Month, Day
X
XXXXX
XXXXX
Revision Table
~
JANUARY/31/2012
CMFB
Summary of Contents for SV8300
Page 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Page 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Page 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...