Chapter 1 MAINTENANCE SERVICES
1-6
NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
Programming Procedure
Fault Message
(1) To set the fault information storage from the PCPro by Command Operation
DESCRIPTION
DATA
Enable the fault information storage feature.
(1)
(2)
450
1 : To store
Assign which kind of fault information is
stored into the fault information memory, and
which kind of alarm is indicated.
•
(1)
(2)
Y=2
See the following table.
See the following table.
NOTE:
CMEA programming can be set by the PCPro.
START
CM08
CMEA
1ST DATA
2ND DATA
DATA
MEANING
DATA
MEANING
Fault Kind: Occurrence
0
3
External Alarm Kind
0: Fault Memory store/No output of
External Alarm
1: Fault Memory store/External Alarm is
MN alarm
2: Fault Memory store/External Alarm is
MJ alarm
3: No Fault Memory store/No External
Alarm output
001
System reset
NOTE 1
012
CS/ZT fault occurred
016
It is a day periodic maintenance
017
Activation Code error occurred during the
License Activation (Center Activation)
021
ISDN D-channel link connection failure
022
CCIS link connection failure
025
Number of lockout stations was more than
predetermined number
NOTE 2
026
DLC blade down
028
SMDR output buffer (SRAM) exceeded 80
%
[8300R3 software required]
029
SMDR output buffer (SRAM) overflow
[8300R3 software required]
02B
CS/ZT fault occurred
02C
LAN application fault occurred
NOTE 3
Continued on next page
~
A
JULY/17/2009