Chapter 2 TROUBLESHOOTING
2-17
NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Remedial Action on Each Fault Kind
FAULT
KIND
NUMBER
FAULT
CONTENT
FAULT INFORMATION
REMEDIAL ACTION
001
System Reset
Reset kind: SENSE switch was
changed to 0
No specific action is required.
Reset kind: Serious failure 7
Replace the CPU blade.
Reset kind: Reset by CAT or PCPro
No specific action is required.
Changeover of Dual CPU System
No specific action is required.
012
CS/ZT fault
Fault Kind Details: Fault notice from
CS/ZT
No specific action is required.
Fault Kind Details: CS/ZT reset failure
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Fault Kind Details: CS/ZT condition
read failure
Fault Kind Details: CS/ZT condition
unmatched
No specific action is required.
Fault Kind Details: B channel condi-
tion unmatched
No specific action is required.
Fault Kind Details: SYS-ID upload
failure
Check the CS/ZT with
SYS-ID is correct by
CMAE Y=00>09.
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Turn OFF and ON the
CS/ZT power switch.
Continued on next page
1
2
1
2
3
APRIL/16/2010