Description
Use
Program 20-03 : System Options for Single Line Telephones
to set up
various options for single line telephones.
Program 20 : System Option Setup
20-03 : System Options for Single Line Telephones
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
Related
Program
01
SLT Call Waiting Answer Mode
For a busy single line telephone, set the mode
used to answer a camped-on trunk call.
0 = Hookflash
(Hooking)
1 = Hoo
Service
Code 654
0
11-12-47
02
Ignore Received DP Dial on DTMF SLT Port
Use this option to define whether the system
should receive dial pulse and DTMF signals
(0) or ignore dial pulse and only accept DTMF
signals (1).
0 = Do Not
Ignore (No)
1 = Ignore (Yes)
0
15-03-01
03
SLT DTMF Dial to Trunk Lines
Type 0:
The system keeps the digits
dialed by the single line telephone on a
trunk in a buffer. After all the digits are
received, the system sends all the digits
to the trunk. If the time space between
digits is longer than the time in Item 4, the
system considers all digits received.
Type 1:
The system passes the received
digits from the single line telephone to the
trunk immediately. If the single line
telephone has a Last Number Dial key
without a pause, this key may not be able
to use the Last Number Dial key with the
Type 1 setting.
When using a third-party external paging
device, set this option to
1
. In addition, set
Program 20-03-04 to
1
. These programs must
be set for Wireless – DECT users to be able
to break dial tone on an analog trunk that is
used for paging.
0 = Receive all
dialed data,
before
sending (All)
1 = Direct
through out
(Direct)
0
20-03-04
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...