Issue 10.1
UNIVERGE SV8100
2 - 12
Program 10 : System Configuration Setup
09
Dial Information Element
ISDN Protocol definition
Only when Dial Sending Mode
(10-03-08) is set for 1 (Overlap
Sending).
0 = Keypad Facility
1 = Called Party Number
1
10
Master/Slave System (Network
Mode only) (OT)
0 = Slave System
1 = Master System
0
11
Networking System Number
(Network Mode only) (OT)
0 - 50
0
12
--- Not Used ---
13
Loss-Of-Signal Detection Limit
If the transmit/receive voltage is less
than the setting in 10-03-13, the
system considers this as Loss-Of-
Signal and the PRTA does not come
up. Note that there are different
values based on the setting in 10-03-
12 for the PRI.
0 = Level 0 (lowest sensitivity)
1 = Level 1
2 = Level 2
3 = Level 3
4 = Level 4
5 = Level 5
6 = Level 6
7 = Level 7 (highest sensitivity)
2
14
Service Protocol for S-point
0 = Keypad facility
1 = Specified Protocol for Aspire
system
0
15
Call Busy Mode for S-point
0 = Alerting
1 = Disconnect
0
16
Two B-Channel Transfer for PRI
Service
0 = off
1 = on
0
17
ISDN Ringback Tone
If Telco does not provide ringback
tone, SV8100 can if 10-03-17 is set to
1:Enable.
0 = Disable
1 = Enable
0
18
Type of Number
ISDN Protocol definition.
Select the number type for the ISDN
circuit.
0 = Unknown
1 = International number
2 = National number
3 = Network Specific number
4 = Subscriber number
5 = Abbreviated number
0
19
Numbering Plan Identification
ISDN Protocol definition.
Select the Numbering Plan used for
the ISDN circuit.
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering
plan
5 = Private numbering plan
0
Item
No.
Item
Input Data
Default
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...