UNIVERGE SV8100
Issue 10.1
Programming Manual
2 - 13
For DTI (T1) PKG Setup
20
Network Exchange Selection
Select the ISDN protocol for the ISDN
circuit.
0 = Standard (same as NI-2)
1 = reserved
2 = reserved
3 = DMS (A211)
4 = 5ESS
5 = DMS (A233)
6 = 4ESS
7 = NI-2
0
21
Number of Ports
0 = Auto
1 = 4 Ports
2 = 8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
6 = 24 Ports
7 = 28 Ports
0
22
QSIG Operation Mode
0 = Disable
1 = Enable
0
23
Straight/Cross Wiring
0 = Auto
1 = Manual (Cross)
2 = Manual (Straight)
0
Physical Port Number
01~30
Item
No.
Item
Input Data
Default
01
Logical Port Number
The start port number of a T1 line is
displayed, and 24 logic ports are
automatically assigned to a DTI (T1)
line.
0~200
0
02
T1 Signal Format Selection
0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
0
03
Zero Code Suppression
0 = B8ZS
1 = AMI/ZCS
0
04
Line Length Selection
0 = 0 feet ~ 133 feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
0
Item
No.
Item
Input Data
Default
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...