Issue 10.1
UNIVERGE SV8100
2 - 510
Program 41 : ACD Setup
Conditions
None
Feature Cross Reference
Automatic Call Distribution (ACD)
Input Data
ACD Group No.
01~64
Item
No.
Item
Input Data
Default
01
Number of Calls in Queue
Set the number of calls that can accumulate in the ACD
queue before the Queue Status Display (and optional
queue alarm) occurs.
0 = No Display,
0~200
0
02
Queue Status Display Time
Set how long the Queue Status display remains on the
telephone display.
0~64800 (sec)
5 (sec)
03
Queue Status Display Interval
Set the interval that refreshes the Queue Status Alarm
time in queue display and causes the optional queue
alarm to occur on phones active on a call, logged out, or
in wrap-up.
0~64800 (sec)
60 (sec)
04
ACD Call Waiting Alarm
Enable or disable the queue alarm.
0 = Disable (Off)
1 = Enable (On)
0
05
ACD Call Waiting Alarm Hold Time
Set how long the Call Waiting Alarm should sound.
0~64800 (sec)
0
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...