UNIVERGE SV8100
Issue 10.1
Programming Manual
2 - 635
Description
Use
Program 50-11: CCIS Centralized Day/Night Switching Sending Group
Assignment
to define Point Code and CCIS Route ID for sending Day/Night
Switching message.
Conditions
None
Feature Cross Reference
None
Program 50 : Common Channel Interoffice Signaling Service
50-11: CCIS Centralized Day/Night Switching Sending Group Assignment
Level:
IN
Input Data
Day/Night Mode Sending Group
1~16
Input Data
Item
No.
Item
Input Data
Default
Description
01
Destination Point Code
0~16367
0
Define the Point Code
for Day/Night Switching.
02
CCIS Route ID
0~8
0
Define the CCIS Route
ID to send Day/Night
Switching messages.
(T1 only)
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...