UNIVERGE SV8100
Issue 10.1
Programming Manual
2 - 717
Description
Use
Program 81-10: COT Initial Data Setup
to define the various basic timers for
each COT trunk port. These timers are only used with a Migration system and only
apply to the Circuit cards installed in the IPKII/IPK chassis.These timers do not apply
to SV8100 blades.
Program 81 : Basic Hardware Setup for Trunk
81-10: COT Initial Data Setup
Level:
IN
Input Data
Trunk port Number.
1~ 200
Item
No.
Item
Input Data
Default
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Select
either Pattern A or pattern B.
0 = Pattern A
(Pattern A: 10pps – 650ms,
20pps – 50ms)
1 = Pattern B
(Pattern B: 10pps – 800ms,
20pps – 80ms)
1
(Pattern B)
02
Prepause Time Selection
Specify the loop open time for a hookflash
signal sent to the CO or PBX when the
Recall key on a multiline terminal is
pressed. A single line telephone (SLT)
generates a hookflash to the CO or PBX
line when a SLT hookflash is assigned.
1~13
(1~13 seconds)
(0 = No Setting)
1
(1sec)
03
Incoming Signal Detect Time Selection
Specify the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
0~15
(50~800ms)
3
(200ms)
04
Disconnect Recognition Time Selection
Specify the minimum time before a
disconnected circuit can be accessed
again.
1~15
(100ms~1.5 seconds)
(0 = No Setting)
3
(300ms)
05
Auto Release Signal Detection Time
Specify the signal detection time for release
of a CO/PBX line after a disconnect signal is
received from the distant CO or PBX.
1~14
(50~700ms)
15 =
(No limit)
(0 = No Setting)
7
(350ms)
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...