UNIVERGE SV8100
Issue 10.1
Programming Manual
2 - 723
Description
Use
Program 81-13: E1 Trunk Timer Setup
to define the basic timer setting of E1
Trunk.
Program 81 : Basic Hardware Setup for Trunk
81-13: E1 Trunk Timer Setup (OT)
Level:
IN
Trunk Port Number
1~200
Item
Name
Input Data
Default
01
Loop Current Detection Time
(Loop)
1~255
(16ms ~ 4080ms)
3
48ms
02
Clear Signal (Open Loop)
Detection Time
1~255
(16ms ~ 4080ms)
50
800ms
03
Transmit Clear Signal Time for
Forced Release
1~255
(16ms ~ 4080ms)
50
800ms
04
Receive DP Inter-digit min. Time
1~255
(4ms ~ 1020ms)
125
500sec
16
Pause Time
1~255
(64ms ~ 16320ms)
47
3008ms
17
Pulse Dial Break Time
1~255
(4ms ~ 1020ms)
15
60ms
18
Pulse Dial Make Time
1~255
(4ms ~ 1020ms)
10
5000ms
19
Pulse Dial Inter-digit Time
1~255
(16ms ~ 4080ms)
50
800ms
20
Receive DP Make min. Time
1~255
(4ms ~ 1020ms)
3
12ms
21
Receive DP Make max Time
1~255
(4ms ~ 1020ms)
19
76ms
22
Receive DP Break min. Time
1~255
(4ms ~ 1020ms)
5
20ms
23
Receive DP Break max Time
1~255
(4ms ~ 1020ms)
26
104ms
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...