Issue 10.1
UNIVERGE SV8100
2 - 870
Program 90 : Maintenance Program
6
0
0
Blocking
The link of terminals
connected with the ESI
package came off.
1.Terminal
Breakdown.
2. Faulty wiring and
wiring termination.
3.External noise.
4.ESI package
Breakdown.
Confirm the terminal
connected with same
ESI. If they work
normally, confirm the
breakdown or the wiring
for the terminal.
Exchange the terminal
that doesn't work and
the working terminal,
and confirm it’s
working. An external
factor of the noise etc.
is thought.
Please reconfirm wiring
and the installation,etc.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
The error is
recovered
when
connecting or
exchanging it.
ERR
REC
7
1
0
Power failure
The supply of the
commercial power
stopped.
1. The power cable
came off.
2. Power failure
3. The power
supply broke down.
1.Confirm the power
supply outlet when the
commercial power has
not stopped.
2.Please confirm with
manufacturer if the
problem occurs again.
When the
commercial
power is
restored, the
error is
recovered.
ERR
REC
8
1
0
RAM Backup
Battery Error
RAM backup battery on the
CD-CP00 blade is
unplugged or defective.
Check the battery
connector. If it is
connected correctly,
replace the battery.
The error is
recovered
once the
battery is
replaced.
ERR
REC
10
0
0
ISDN Link
Error
Layer1 link of ISDN lines
came off.
1. Check
Connection
between main
device and ISDN
line
2. DSU Breakdown.
3. The setting of
PRG10-03 does
not correspond to
an actual line.
1.Confirm the data of
PRG10-03.
2.Confirm wiring and
the installation of DSU.
3.Check with the
manufacturer if the
problem occurs again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
11
0
0
CTI Link Error
The link with the CTI server
came off.
1. LAN cable
defective.
2. Connected HUB
broken.
3. The CTI server
doesn't start
normally.
1. Confirm the CTI
server, wiring, and the
connection.
2.Check the
manufacturer if the
problem occurs again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
12
0
0
ACD MIS Link
Error
The link with ACD MIS
client PC came off.
1. LAN cable
defective.
2. Connected HUB
broken.
3. The CTI server
doesn't start
normally.
1.Confirm ACD MIS
client PC and
connected part.
2. Check with
manufacturer if the
problem occurs again.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...