2 - 63
Description
(This program is aviable for V7000 or higher for AU)
Use
Program 10-41: General Purpose Contact Detector Setup
to specify the
circuit number used on a PGD Adapter as a contact detection circuit.
Conditions
None
Feature Cross Reference
Analog Communications Interface (ACI)
Program 10 : System Configuration Setup
10-41: General Purpose Contact Detector Setup
Level:
IN
Input Data
General Purpose Contact Detector Number
1-8
Item
No.
Item
Input Data
Default
01
System ID
The user can set System ID when the Link is
active
0: Not Using the NetLink
1 - 50: System ID
0
Slot Number
Define the slot number of the DLC to which the
PGD Adapter is connected
0 = No Setting
1-24 = Slots 1-24
0
02
Physical Port Number
Select the port number on the DLC to which
the PGD Adapter is connected.
0 = No Setting
1-16 = Ports 1-16
0
03
Relay Circuit Number
Select the relay circuit on the PGD Adapter
module.
0 = No Setting
1-2 = Circuit Number 1-2
0
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...