UNIVERGE SV8100
Issue 4.1
System Hardware Manual
4 - 15
To perform a system software and firmware upgrade:
1.
Turn the system power off.
2.
Once the system has powered down, insert the USB Memory
containing the software upgrade into the USB port on the
CD-CP00.
3.
Push in and hold the
Load
button.
4.
Turn the system power on.
5.
Continue holding the
Load
button for approximately 10
seconds or until Status LED5 begins flashing red.
6.
Release the
Load
button.
7.
Wait until the Status LEDs on the CD-CP00 have the following
indications (approximately two minutes):
LED 2: Flashing Red
LED 3: Flashing Red
LED 4: Flashing Red
LED 5: Steady Red
8.
Turn the system power off and un-install the USB Memory.
9.
Turn the system power back on.
10.
When the system has completed reloading the software, the
Status LED begins flashing on the CD-CP00. The remaining
four LEDs are off.
To confirm the new software version has been installed, the
system version number can be viewed by pressing the
F 3 keys on any display multiline terminal.
The existing system software in the flash memory is replaced,
but the customer data (stored in the RAM) is saved.
Summary of Contents for Univerge SV8100
Page 1: ...System Hardware Manual Issue 4 1 February 2011...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...Issue 4 1 UNIVERGE SV8100 1 14 Introduction to SV8100...
Page 68: ...Issue 4 1 UNIVERGE SV8100 2 32 SV8100 System Specifications...
Page 99: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 3 31 Figure 3 34 Install Screws Option 2...
Page 148: ...Issue 4 1 UNIVERGE SV8100 3 80 Installing the SV8100 Chassis...
Page 247: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 4 99 Figure 4 34 Control Signal Connection...
Page 258: ...Issue 4 1 UNIVERGE SV8100 4 110 Installing the SV8100 Blades NOTES...
Page 418: ...Issue 4 1 UNIVERGE SV8100 6 64 Installing SV8100 Optional Equipment...