Issue 4.1
UNIVERGE SV8100
4 - 54
Installing the SV8100 Blades
The 4SLIU and 8SLIU are not rated for OPX use. A 4DIOPU blade
should be used instead (it supports the analog DID and single line
telephone interface functions, such as Off-Premise Extensions).
One extension status LED
Two blade status LEDs
Constant current type battery feeding (25mA / -28Vdc)
DC Voltage (On hook) (-28Vdc)
Feeding Polarity Reverse Ability
Connector for PZ-4LCA/PZ-8LCE Daughter Boards
Ring Generator (75Vrms, 16Hz/20Hz/25Hz selectable by CM82-04-02)
Caller ID Sending Ability
Message Wait Lamping Ability (110V DC)
Cable length = 600ohms (including the SLT). Approximately 1Km
The CD-8LCA consumes eight ports ranging between ports
001~256. The CN3 and CN5 connectors each provide connection to
four analog station ports. The CNx connectors are not polarity
sensitive.
Table 4-25 CD-4LCA/CD-8LCA Maximum Upgrade Capacities
SLIU
19”
Chassis
with CPU
19” Chassis
without CPU
19” Chassis
x4
Networked
Chassis
CD-4LCA
5
6
23
32
CD-8LCA
5
6
23
32
Summary of Contents for Univerge SV8100
Page 1: ...System Hardware Manual Issue 4 1 February 2011...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...Issue 4 1 UNIVERGE SV8100 1 14 Introduction to SV8100...
Page 68: ...Issue 4 1 UNIVERGE SV8100 2 32 SV8100 System Specifications...
Page 99: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 3 31 Figure 3 34 Install Screws Option 2...
Page 148: ...Issue 4 1 UNIVERGE SV8100 3 80 Installing the SV8100 Chassis...
Page 247: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 4 99 Figure 4 34 Control Signal Connection...
Page 258: ...Issue 4 1 UNIVERGE SV8100 4 110 Installing the SV8100 Blades NOTES...
Page 418: ...Issue 4 1 UNIVERGE SV8100 6 64 Installing SV8100 Optional Equipment...