Installing the ADA-L UNIT
Perform the following steps to connect the ADA-L UNIT to the
Bottom Option Interface located underneath the DTL/ITL multiline
terminal.
.
Only one ADA-L UNIT can be installed at a time.
1.
Unplug the line cord from the keyset.
2.
Turn the DTL/ITL multiline terminal upside down.
3.
Lower the tilt leg to the first position (refer to
Figure 6-24
Separate Tilt Leg from Leg Support
).
Dip
Switches
(DSW)
DSW 1
Output Hook Signal to External Device
On = Output
Off = No Output (Default)
DSW 2
Record Confirmation Tone
On = Tone On
Off = Tone Off (Default)
DSW 3
and
DSW 4
Use T1/T2
On = Disable (Default)
Off = Enable
.
Do not connect T1 and T2 when DSW switches 3 and 4 are On.
Figure 6-24 Separate Tilt Leg from Leg Support
Table 6-3 ADA-L Unit Switch Settings (Continued)
Switch
Description/Settings
To prevent possible damage to the ADA-L
UNIT or the DTL/ITL multiline terminal
during installation or removal, disconnect
the line cord/LAN cable and the AC/DC
adapter from the DTL/ITL multiline terminal.
Stoppers
Tilt Leg
Summary of Contents for Univerge SV8100
Page 1: ...System Hardware Manual Issue 4 1 February 2011...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...Issue 4 1 UNIVERGE SV8100 1 14 Introduction to SV8100...
Page 68: ...Issue 4 1 UNIVERGE SV8100 2 32 SV8100 System Specifications...
Page 99: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 3 31 Figure 3 34 Install Screws Option 2...
Page 148: ...Issue 4 1 UNIVERGE SV8100 3 80 Installing the SV8100 Chassis...
Page 247: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 4 99 Figure 4 34 Control Signal Connection...
Page 258: ...Issue 4 1 UNIVERGE SV8100 4 110 Installing the SV8100 Blades NOTES...
Page 418: ...Issue 4 1 UNIVERGE SV8100 6 64 Installing SV8100 Optional Equipment...