Issue 4.1
UNIVERGE SV8100
2 - 16
SV8100 System Specifications
S
ECTION
5
S
YSTEM
R
EQUIREMENTS
AND
S
PECIFICATIONS
5.1
Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV8100 system.
Figure 2-4 Connecting the DLC Using Twisted 2-Pair Cable
is a diagram of the
chassis connected with each of the multiline terminals and single line
telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline
Terminals).
Refer to the following tables for cabling requirements and specifications.
Table 2-12 DT300 Series Loop Resistance and Cable Length
Table 2-13 DT700 Series Loop Resistance and Cable Length
Table 2-14 D
term
Series i or D
term
IP Terminal Loop Resistance and Cable
Length
Table 2-15 Cable Connection Between the Analog Port and the Single Line
Equipment
Table 2-16 Cabling Requirements
Figure 2-4 Connecting the DLC Using Twisted 2-Pair Cable
Table 2-12 DT300 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
By Twisted 1-Pair
Cable (with AC
Adapter)
24 AWG
DTL-2E-1 (BK) TEL
1,969 ft (600m)
6,562 ft (2000m)
DTL-6DE-1 (BK) TEL
1,969 ft (600m)
6,562 ft (2000m)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
1,969 ft (600m)
6,562 ft (2000m)
DTL-12BT-1 (BK) TEL
1,969 ft (600m)
6,562 ft (2000m)
DTL-12PA-1 (BK) TEL
1,969 ft (600m)
6,562 ft (2000m)
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
1,969 ft (600m)
6,562 ft (2000m)
Multiline Terminal
Twisted 2-Pair Cable
DLC
RJ-11
Summary of Contents for Univerge SV8100
Page 1: ...System Hardware Manual Issue 4 1 February 2011...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...Issue 4 1 UNIVERGE SV8100 1 14 Introduction to SV8100...
Page 68: ...Issue 4 1 UNIVERGE SV8100 2 32 SV8100 System Specifications...
Page 99: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 3 31 Figure 3 34 Install Screws Option 2...
Page 148: ...Issue 4 1 UNIVERGE SV8100 3 80 Installing the SV8100 Chassis...
Page 247: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 4 99 Figure 4 34 Control Signal Connection...
Page 258: ...Issue 4 1 UNIVERGE SV8100 4 110 Installing the SV8100 Blades NOTES...
Page 418: ...Issue 4 1 UNIVERGE SV8100 6 64 Installing SV8100 Optional Equipment...