Issue 4.1
UNIVERGE SV8100
2 - 26
SV8100 System Specifications
5.6.7
External Tone Ringer/Night Chime Output
Output Level: –10 dBm
Output Impedance: 600
Ω
Relay Contact Rating: 500 mA, 24 Vdc
5.6.8
SMDR Output
Female Connector (LAN) Standard DB-9 (straight)
5.6.9
PC Connection
Female Connector (LAN) Standard DB-9 (straight)
5.6.10
Relay Contact
All Relay Contact Ratings: 500 mA, 24Vdc
5.7
Battery Backup
The UNIVERGE SV8100 system has battery backup functions for system
backup and for memory backup.
5.7.1
System Backup (Optional)
During a power failure, the system can be backed up using the
CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the
CHS LARGE BATT SETs for a backup time ranging from 45~180
minutes.
5.7.2
Memory Backup
The CD-CP00 Blade battery retains the Clock/Calender and Last
Number redial (LNR) buffers for each station when the CD-CP00
Blade encounters a power loss. With a fully charged battery, the
settings are retained for about three years. The System Programmed
memory (Customer Database) is stored in non-volatile Memory and
can be erased only by a First Initialization. After power is restored,
the system Blade returns to normal operation.
Summary of Contents for Univerge SV8100
Page 1: ...System Hardware Manual Issue 4 1 February 2011...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 36: ...Issue 4 1 UNIVERGE SV8100 1 14 Introduction to SV8100...
Page 68: ...Issue 4 1 UNIVERGE SV8100 2 32 SV8100 System Specifications...
Page 99: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 3 31 Figure 3 34 Install Screws Option 2...
Page 148: ...Issue 4 1 UNIVERGE SV8100 3 80 Installing the SV8100 Chassis...
Page 247: ...UNIVERGE SV8100 Issue 4 1 System Hardware Manual 4 99 Figure 4 34 Control Signal Connection...
Page 258: ...Issue 4 1 UNIVERGE SV8100 4 110 Installing the SV8100 Blades NOTES...
Page 418: ...Issue 4 1 UNIVERGE SV8100 6 64 Installing SV8100 Optional Equipment...