Issue 1.0
UNIVERGE SV9100
2 - 10
No Outside Dial Tone Access
Multiline
Terminal or SLT?
SLT
Check for Internal
Dial tone.
Check for Internal
Dial tone.
Internal
Dial Tone?
Internal
Dial Tone?
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
1. Perform Second
Initialization.
2. Reset and test
GCD-4LCA
/
GCD-8LCA
3. Replace and test
GCD-4LCA
/
GCD-8LCA
.
1. Reset terminal
and test.
2. Replace terminal
OR
Reset GCD-8DLCA
and test.
3. Replace GCD-8DLCA
and test.
Leave an GCD-4LCA
.
GCD-8LCA
and an
GCD-8DLCA
installed. Go
to Flowchart A1.
All
Terminals
affected?
Check for Internal
Dial tone.
Internal
Dial Tone?
Go to Flowchart
A1.
Test for CO dial
tone at MDF with
test set, and check
CO wiring.
Have Telco
check lines.
1. Check PRG 21-04 and PRG 14-01-07
for Station Restriction.
2. Check PRG 15-06 for Trunk access.
Check conduit and frame ground to
system for ground start trunks.
CO
Dial Tone?
1. Reset and test; replace GCD-4COTB
and test. If trouble persists go to step 2.
2. Perform Second Initialization. If trouble persists go to step 3.
3. Perform First Initialization. If trouble persists go to step 4.
4. Replace GCD-CP10, and test using default program.
C3
Both
Multiline Terminal
Summary of Contents for Univerge SV9100
Page 1: ...System Maintenance Manual NDA 31584 Issue 1 0 SV9100...
Page 2: ......
Page 4: ......
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...Issue 1 0 UNIVERGE SV9100 1 6 Figure 1 3 Trace File Example...
Page 38: ...Issue 1 0 UNIVERGE SV9100 2 22 NOTES...
Page 75: ...UNIVERGE SV9100 Issue 1 0 System Maintenance Manual 3 37 NOTES...
Page 76: ...Issue 1 0 UNIVERGE SV9100 3 38...
Page 77: ......
Page 78: ...System Maintenance Manual NEC Corporation of America Issue 1 0 SV9100...