UNIVERGE SV9100
Issue 1.0
System Maintenance Manual
3 - 13
Real unit ID : 12H
Version : 1.8
Firmware loaded onto the Blade
Lines / unit : 8
Number of ports on the card (8ESIU)
Block switch : RUN
Block switch set to RUN
Timeslot : 000H-00FH (16)
slot info 03
Slot information)
Slot ID : 3
Status : RUNNING
Logical unit ID : BRIU
Dump down message : Disable
Number of Tx errors : 0
Slot started delay : 468.99sec.
Common unit driver information)
Slot ID : 3
Real unit ID : 60H
Version : 3.3
Firmware loaded onto the blade
Lines / unit : 2
Number of ports on the card (2BRIU)
Block switch : BLOCK
Block switch set to BLOCK
Timeslot : 040H-043H (4)
BRIU driver information)
To reset the Blade installed in a slot:
slot reset nn
Where nn is the slot number 01 to 10 in hexadecimal.
The Blade is reset, any calls in progress at the Blade are disconnected.
The Blade operates normally after the reset.
The reset has the same operation as removing and re-installing the Blade.
(example – to reset the Blade in slot 3 =
slot reset 03
)
Detector
Enter
Function
DIM Output
Detector
List the status of the
DTMF/Tone detectors on
the GCD-CP10 (and
DSPDB if installed).
Number of Channels = 64
CPRU = 32 , DSPDBU = 32
No Type Status Target
01(1401) DTMF ACTIVE 000d
02(0000) NOT USED READY 0000
03(0000) NOT USED READY 0000
04(0000) NOT USED READY 0000
05(0000) NOT USED READY 0000
: : : :
64(0000) NOT USED READY 0000
Summary of Contents for Univerge SV9100
Page 1: ...System Maintenance Manual NDA 31584 Issue 1 0 SV9100...
Page 2: ......
Page 4: ......
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...Issue 1 0 UNIVERGE SV9100 1 6 Figure 1 3 Trace File Example...
Page 38: ...Issue 1 0 UNIVERGE SV9100 2 22 NOTES...
Page 75: ...UNIVERGE SV9100 Issue 1 0 System Maintenance Manual 3 37 NOTES...
Page 76: ...Issue 1 0 UNIVERGE SV9100 3 38...
Page 77: ......
Page 78: ...System Maintenance Manual NEC Corporation of America Issue 1 0 SV9100...