UNIVERGE SV9100
Issue 1.0
System Maintenance Manual
3 - 29
SET_CALL_REF CALLED!
PHYSICAL_W =0108HSET_CALL_REF: PRI =8004H
*** set_call_ref resource# : 1H ***
<<< prgrd1501.cpp(38) read_s_sta_clip_enable >>> port : 0, data : 1
S ISDN : >>>>>>>>>>>>>>>>
F4 A1 04 01 01 00
USL(8,1),SETUP REQ
08 02 00 04 05
Callref:ORG(4),SETUP
04 03 80 90 A3
Bearer capability [speech]
18 03 A9 83 81
Channel identification
6C 02 00 81
Calling party number
7C 03 80 90 A3
Low layer compatibility
7D 02 91 81
High layer compatibility
>>>> PORT:3415H STATUS 00D0H => 00B1H
*(EVENT),ID:0000H,P1:3415H,P2:0001H,P3:09F9H,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:0401H,P2:0001H,P3:000BH,P4:0000H,P5:0000H
== 1/JAN/2002, 10:12 ==
*(EVENT),ID:0004H,P1:080BH,P2:0000H,P3:E07D4F8H,P4:0000H,P5:0000H
R ISDN : <<<<<<<<<<<<<<<<
15 0B A1 0F 01 01 00
USL(8,1),MORE INFO IND
08 02 80 04 0D
Callref:DES(4),SETUP ACKNOWLEDGE
18 03 A9 83 81
Channel identification
1E 02 82 88
Progress indicator
PHYSICAL_W =0108H..... 3415(00B1-0401) 098E
itr_cint_mrifind called
>>>> PORT:3415H STATUS 00B1H => 00B2H
*(INTER),ID:3415H,P1:0401H,P2:0000H,P3:08EAH,P4:0000H,P5:0000H
*(INTER),ID:3415H,P1:0401H,P2:0000H,P3:08EBH,P4:0000H,P5:0000H
== 1/JAN/2002, 10:12 ==
*(EVENT),ID:0000H,P1:0401H,P2:0002H,P3:000AH,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:3415H,P2:0000H,P3:097FH,P4:0000H,P5:0000H
S ISDN : >>>>>>>>>>>>>>>>
F4 A1 0E 01 01 00
USL(8,1),INFO REQ
08 02 00 04 7B
Callref:ORG(4),INFORMATION
70 02 81 32
Called party number [2]
*(EVENT),ID:0000H,P1:0401H,P2:0000H,P3:08E6H,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:0401H,P2:0000H,P3:08E6H,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:0401H,P2:0002H,P3:000BH,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:0401H,P2:000AH,P3:000AH,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:3415H,P2:0000H,P3:097FH,P4:0000H,P5:0000H
S ISDN : >>>>>>>>>>>>>>>>
F4 A1 0E 01 01 00
USL(8,1),INFO REQ
08 02 00 04 7B
Callref:ORG(4),INFORMATION
70 02 81 30
Called party number [0]
*(EVENT),ID:0000H,P1:0401H,P2:000AH,P3:000BH,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:0401H,P2:000AH,P3:000AH,P4:0000H,P5:0000H
*(EVENT),ID:0000H,P1:3415H,P2:0000H,P3:097FH,P4:0000H,P5:0000H
S ISDN : >>>>>>>>>>>>>>>>
F4 A1 0E 01 01 00
USL(8,1),INFO REQ
08 02 00 04 7B
Callref:ORG(4),INFORMATION
70 02 81 30
Called party number [0]
*(EVENT),ID:0000H,P1:0401H,P2:000AH,P3:000BH,P4:0000H,P5:0000H
*(EVENT),ID:0004H,P1:080BH,P2:0000H,P3:DF080F8H,P4:0000H,P5:0000H
The trace will be the
same as the previous
listing, but with
additional information
included related to the
operation of the SV9100
system.
Summary of Contents for Univerge SV9100
Page 1: ...System Maintenance Manual NDA 31584 Issue 1 0 SV9100...
Page 2: ......
Page 4: ......
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...Issue 1 0 UNIVERGE SV9100 1 6 Figure 1 3 Trace File Example...
Page 38: ...Issue 1 0 UNIVERGE SV9100 2 22 NOTES...
Page 75: ...UNIVERGE SV9100 Issue 1 0 System Maintenance Manual 3 37 NOTES...
Page 76: ...Issue 1 0 UNIVERGE SV9100 3 38...
Page 77: ......
Page 78: ...System Maintenance Manual NEC Corporation of America Issue 1 0 SV9100...