ISSUED: 11-16-05 SHEET #: 055-9447-2
Visit the Peerless Web Site at www.peerlessmounts.com
3 of 8
For customer service call 1-800-729-0307 or 708-865-8870.
Accessories listed in the included sheet, as well as other parts,
can be ordered through Peerless by calling 1-800-729-0307 or
visiting www.peerlessindustries.com.
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach projector mount assembly (A) with two
#14 x 2.5" (6 mm x 65 mm) wood screws (F) and two flat washers (E) as shown in figure 1 or figure 2 depending
on joist orientation. Tighten wood screws (F) using 3/8" (10 mm) socket wrench until projector mount assembly (A)
is firmly attached.
Note: Be sure to drill holes into the joist CENTER!
Skip to step 6.
Installation To Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings
F
F
A
WOOD JOIST
FRONT OF
MOUNT
E
E
FRONT OF
MOUNT
WOOD JOIST
A
figure 1
figure 2
Disengage connection block from projector mount assembly (A) by unscrewing captive screw and sliding out
connection block as shown.
CONNECTION BLOCK
CAPTIVE SCREW
A
• Do not tighten screws with excessive force.
Overtightening can cause damage to mount. Tighten
screws to 40 in. • lb (4.5 N.M.) maximum torque.
CAUTION
• Installer must verify that the ceiling will safely support
the combined laod of equipment and all attached
hardware and components.
WARNING