3-Minute Alarm Selection
1 - 387
Programming Manual
May 2003
A6-
324000-6
42-02 -
Release 6.0
May 2003
4-94
System Mode
4
Submode
—
Data No.
94
PC Programming
a
+BTM
3-Minute Alarm Selection
General Description
Use this Memory Block to specify, per station, whether or not a warning signal tone is
generated at 3-minute intervals during an outgoing or incoming CO/PBX call.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the default setting.
No
Ys
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK4 +
ID
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change data option.
Note:
Use the following to change option:
R
select next Tel Port No.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. A 1-second (approximately) warning signal sounds every 3 minutes during CO/PBX calls.
2. The alarm tone is heard through the terminal speaker only.
3. If the built-in speakerphone is used for Handsfree, the warning signal is not used.
4. Telephone ports A0~C0 are ports 100~120.
0 1 / 9 4 : 3 m A L M
N O
T I M E
D I S P L A Y
Data
No.
Tel Port No.
(01~99)
A0~C0
Title
Setting
Data