May 2003
Programming Manual
1 - 23
A
6
-324000
-642-
02 - Re
lease 6.0
May 20
03
29
Trunk Internal Transmit Pad Selection
2 dB
2 dB, 4 dB, 6 dB, 8 dB, 12 dB, 16 dB, 3 dB,
-3 dB, 0 dB
30
Trunk Internal Receive Pad Selection
4 dB
2 dB, 4 dB, 6 dB, 8 dB, 12 dB, 16 dB, 3 dB,
-3 dB, 0 dB
31
Trunk External Transmit Pad Selection
0 dB
2 dB, 4 dB, 6 dB, 8 dB, 12 dB, 16 dB, 3 dB,
-3 dB, 0 dB
32
Trunk External Receive Pad Selection
0 dB
2 dB, 4 dB, 6 dB, 8 dB, 12 dB, 16 dB, 3 dB,
-3 dB, 0 dB
33
Disconnect Recognition Time Selection
2.0 sec.
0 sec., .2 sec., .3 sec., .5 sec., .7 sec.,
.9 sec.,
1.0 sec., 1.2 sec., 1.4 sec., 1.5 sec., 1.7
sec., 1.9 sec., 2.0 sec., 2.2 sec., 2.4 sec.,
2.6 sec.
38
Automated Attendant Message to
Message 1
Message 1~8
39
Yes
Yes, No
41
Refer to ACD/UCD Delay Announcement Assignment on page 1-299.
42
No Assignment
Station No.
43
No Assignment
Station No.
44
Caller ID Display Assignment for CO/
Not Specified
Telephone Port 01~96
45
Live Recording Trunk Selection
No
No = No Live Recording
Yes = Live Recording
52
Not Specified
Up to 13 digit per a CO/PBX Port No.
53
Caller Name Indication Selection
Trunk Name
No Indication, Caller No. Indication, Name
Indication (by SPD), Trunk Name
59
Normal
Normal, Delay Announcement
61
DIT Delay Answer Timer Selection
Trunks (1-64) = 0 sec.
0s, 5s, 10s, 20s, 30s, 40s, 50s, 60s
62
All CO/PBX Lines are
set to tenant 00
Trunk (1-64) can be set to a tenant (00-47)
63
Holiday DIT = YES
NO, YES
64
DIT Night Mode Delay Answer Enable
Night DIT = NO
NO, YES
65
All CO/PBX lines are
set to “NON”
NON, MSG1, MSG2, MSG3, MSG4,
MSG5, MSG6, MSG7, MSG8
67
CO Line Ringing Pattern Selection for
— = NON
Pattern A~H
LK 3 CO/PBX Line Mode (Continued)
Data
No.
Memory Block Name
Default Value
Programming Values